Newmar Power
Newmar PT-14W Battery Charger [PT-14W]
Newmar PT-14W Battery Charger [PT-14W]
PT-14W Battery Charger
Newmar’s Phase Three Series Battery Chargers employ “Smart” battery charging technology for 12-volt systems aboard marine applications including workboats, military vessels, commercial vessels, and recreational craft. This charger interacts with batteries, providing the optimum three-stage charge process for fast recovery and conditioning, maximizing performance, and extending battery life.
A selector switch adjusts output voltage to adapt to gel-cell, flooded lead-acid, or AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries’ ambient temperature. This model is housed in a rugged stainless-steel case with a durable white powder coat finish, and the internal circuitry is polyurethane-coated for maximum corrosion resistance.
Features:
- “Smart” circuitry provides three-stage charging – bulk, absorption, float
- Gel-Cell/Flooded Lead-acid/AGM battery type switch selects optimum charge/float voltages
- Multiple isolated output banks; ammeter indicates total output current. (Except PT-7)
- The optional sensor adjusts output voltage based on battery temperature. (Except PT-7)
- Current limiting prevents damage from overloading
- Clean well-regulated output can be used as a power supply; can power loads directly without a battery in line
- Built to last – rugged stainless-steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry
- Protection: Current Limiting, Thermal Protection, Forced Air Cooling, Drip Shield
- ABS-type approval for battery charging and power supplies
Specifications:
- Input VAC (50-60 Hz.): 85-264
- Input Amps @ Full Load: @ 115 VAC: 2.8, @ 230 VAC: 1.4
- P.F. Rating: .93@230V and .98@115V
- Max Output Amps: 14
- Output Banks: 3
- Battery Capacity (Amp-Hours): 28-140
- Operating Temp. Rating Reference: T-2
- Case Size Reference: A-2
- Case Size (H x W x D): 11.2A x 7.7 x 4.75A inches (31.8A x 19.6 x 12.1A centimeters) *Note with Dripshield installed A add 1.1” (2.8 cm) to height and .92” (2.3 cm) to depth
- Weight Lbs./Kg: 8/4
- Optional Temp. Sensor Model: TCS-12/24
- Remote Panel Model: RP
- Equalize Option: Yes
- Output Indicator Reference: M-3
- Compliance Reference: CG, CE
Temperature Rating References:
- Temperature: -10 degrees C to +60 degrees C
- Derate Linearly From 100% @ 40 degrees C to 60% @ 60 degrees C
Nominal Output Voltages at Gel/Flooded Switch Settings (without Temperature Compensation):
- Gel-Cell: 14.0 VDC Charge @ 50% load and 13.6 VDC Float @ .5 amp load
- Flooded/AGM: 14.2 VDC Charge @ 50% load and 13.4 VDC Float @ .5 amp load
Compliance References:
- CG: USCG CFR 183.410 (Ignition protected)
- CE: Carries the CE mark
- ABS: PT Series meets SVR 2009 4-8-3/5.9, Under 90 meters Rules 2006 4-6-4/7.19, and HSNC 2007 4-8-3/5.13.
Options:
- Remote Panel, model RP, for use with all models except PT-7 and PT-40U (LEDs indicate the charger output stage. Manual re-initialization of a three-stage charge cycle. With 25′ of cable. Panel dimensions: 3″ H x 4.75″ W)
Specifications:
- Charger Input - Voltage: 115/230v
- Charger Output - Amps: 14a
- Charger Output Voltage: 12v
- Charging Banks: 3
- Inverter Input Voltage: 115/230v
- Inverter Output Voltage: 115/230v
- Outlet Qty: Hardwire
- Portable: No
- Box Dimensions: 11"H x 11"W x 16"L WT: 9.5 lbs
Quick Guide (pdf)
Owner's Manual (pdf)